top of page

MICROSCOPY

REINVENTED

FUS-2000

Fully automated urine R&M analyzer

A fully automated walk-away hybrid that combine result from chemistry & microscopy. 

Fully automated urine R&M analyzer

FUS-2000

Fully automated urine R&M analyzer

Through the combination of intelligent dry chemistry and imaging technology comparison, the FUS-2000 provides the user with precise data, effectively lowering the risk of both false positive and false negative results.

 

  • High precision aspiration and dripping system guarantees accurate sample distribution on the urine strips.

  • Patient ID is automatically recognized by the bar code reading system.

  • STAT port provides emergency sample priority.

  • Blank pad for the correction of influence from urine color variation.

 

 

potus medical website-02.jpg

Features

  • Auto loader capacity: 50 samples/ 270 samples optional

  • High throughput: 120 tests/hour

  • Simplified and compact 2 in 1 design

  • Standardized urinalysis testing solution 

  • Long walk-away operation with consecutive loading (50/270 samples optional)

  • Contributing comprehensive clinical information to doctors

Urine chemistry menu:

  • Urobilinogen

  • Bilirubin

  • Ketones

  • Blood

  • Protein

  • Nitrite

  • Leucocyte

  • Glucose

  • PH

  • Creatine

  • Cacium

  • Vitamin C

  • Microalbumin

  • Specific Gravity

  • Color

  • Turbidity

Urine formed element / sediments menu:

  • Red blood cell

  • White blood cell

  • Squamous epithelial cell

  • Non-squamous epithelial cell

  • Hyaline casts

  • Unclassified casts

  • Mucus

  • Bacteria

  • Yeast

  • White blood cell

  • clumps

  • Sperm, etc

Test Principle

The FUS-2000 utilizes flat flow cytometry, digital imaging technology and All technique to not only provide the user with objective results but also with physical images

 

 

Photo Gallery

R & M analyzer - spec

Specification

Sample types: Urine

Sample loading: 50/270 samples(optional)

Throughput: 120 T/H
Sample volume: Minimum volume: 3ml; aspiration volume: approx. 2.0ml

Urinalysis System: Windows XP operating system, Bidirectional to LIS/HIS
Memory capacity: 100,000 or more records
External output: RS-232 USB Net Port
Operation condition: 15-35
Humidity: 75%
Weight: 82kg(with reclaiming tray 114kg)
Dimension: 779mm 688mm 584mm (L W H)
Power supply: ~100-240V 50HZ/60HZ
Printer: 
External printer

Urine chemistry

Throughput: 240 T/H
Sample volume: Minimum volume: 2ml; aspiration volume: 1.2ml
Analysis parameters: Urobilinogen, Bilirubin, Ketones, Blood, Protein, Nitrite, Leucocyte, Glucose, PH,Creatinine,Calcium,Vitamin C, Microalbumin, Specific Gravity, Color, Turbidity

Principles: Photoelectric colorimetry
Wavelength: 525nm 572nm 610nm 660nm
Max loading strips: 200 strips

Urine formed elements

Throughput: 120 T/H
Sample volume: Minimum volume: 3ml; aspiration volume: 2.0ml
Analysis parameters: Red blood cell,White blood cell,Squamous epithelial cell,Non-squamousepithelial cell,Hyaline casts,unclassified casts ,Mucus,Bacteria,Yeast,White blood cell clumps,Sperm

Research parameters: RBC information
Methods: Flow cytometryDigital imaging technologyAII software